SOLUTIONS · INTELLIQUALITY

Catch the defectbefore itships.

Predictive quality across every station.

IntelliQuality learns how readings across your stations, tools and part lots combine into defects, returns and warranty claims. It scores every unit as it moves down the line and tells your team which ones to check, and why, while they are still in the plant.

UNIT 027830Front door water leak
One unit's water-leak risk, station by station Risk stays near the plant median through body, paint and chassis, then jumps to 23 times the median at the final-line seal station, above the alert threshold. 0×10×20×30× ALERT THRESHOLD BodyPaintChassisFinalEnd of lineBody: 2.3× the plant medianPaint: 2.9× the plant medianChassis: 1.8× the plant medianFinal: 23.0× the plant medianEnd of line: 25.2× the plant median Sealer bead5.74 mm · in spec Door seal 10.48 mm · in specRisk 23× plant median FLAGGED WATER-LEAK RISK · × PLANT MEDIAN
Illustrative. Based on a simulated assembly plant generated by IntelliMake’s plant simulator.
18×better than station limits at ranking units at risk, median across 15 plants
1 in 4escapes found by checking only the riskiest 1% of units, against 1 in 46 with station limits
6 minto configure four new plants from their own data, with no code changes
15 sto take in a full day of live plant messages

Results from an independent benchmark on 15 plants generated by IntelliMake’s plant simulator, four of them held back until the software was frozen. Figures are illustrative.

01 / THE PROBLEMQUALITY ESCAPES HIDE BETWEEN STATIONS

Every station in control.
The unit still fails.

Statistical process control watches one characteristic at one station, and it does that job well. But many field failures come from combinations: two readings that are each in specification, a tool that is drifting, a part lot that runs slightly off. No single chart can see them. IntelliQuality reads the whole build record of every unit, so it can.

SEALER BEAD WIDTHHem sealer · body shop · mm IN CONTROL0 of 31,539 out of spec USLUCLx̄LCLLSL SEAL SEATED DEPTHSeal roller · final line · mm IN CONTROL0 of 31,539 out of spec USLUCLx̄LCLLSL
Two stations, both in control. Not one of 31,539 units is outside its limits at either station.
5.05.56.06.57.08.59.510.511.5 Sealer bead width at the hem sealer (mm) · spec 5.0–7.0 Door seal depth at the seal roller (mm) · spec 8.5–11.5 19×leak rate where a narrowbead meets a deep seal
Read together, the failures stand out. Where a narrow sealer bead meets a deep door seal, 6.2% of units leak, against 0.33% elsewhere. That pocket holds 5% of units and 50% of all leaks. leak claim no claim

Illustrative. Based on a simulated assembly plant generated by IntelliMake’s plant simulator.

02 / HOW IT WORKSFROM YOUR DATA TO A DECISION ON EVERY UNIT

Connect. Learn.
Decide. Improve.

IntelliQuality sits beside the systems you already run. It does not replace your MES, your historians or your inspectors. It gives them a ranked, explained view of risk that none of them has on its own.

01 / CONNECT

Your data, as it is

Production records, measurements, genealogy, defects and claims come in from files or live message feeds. Each vendor format is mapped once, in the browser, without code.

02 / LEARN

Models for each failure

IntelliQuality learns, for each failure you care about, which combinations of readings, tools, lots and shifts precede it. Every model is tested on later production before it goes live.

03 / DECIDE

A score at every station

Each unit is scored as it completes each station. When risk crosses your threshold, the right person gets an alert with the reasons, and a hold can be written back to your MES.

04 / IMPROVE

Causes, not just alerts

Root-cause findings name the station, tool, characteristic or part lot, when it started, how many units to contain, and who owns the fix. Outcomes feed the next model.

03 / IN THE PRODUCTANSWERS IN YOUR PLANT’S LANGUAGE

Not a score.
A reason to act.

Every alert says which unit, which failure, how much risk and why, in the names your engineers already use. Every finding comes with the evidence behind it and the units it affects.

ALERT QUEUEFinal line · Seal roller
HIGH RISK

Unit 027830 · Front door water leak

Risk 23× the plant median after the seal roller

23×vs median

WHY THIS UNIT

  • Door seal depth10.48 mm
    Seal roller, final line · in spec (8.5–11.5) · deeper than 94% of units
  • Sealer bead width5.74 mm
    Hem sealer, body shop · in spec (5–7) · narrower than 86% of units

This combination carries 19× the usual leak rate in this plant’s history.

Hold for water testReleaseAssign
ROOT CAUSEFront door water leak
#FindingLeak rate vs restSinceUnits to containOwner
1Hinge bolt angle × Part lot L2504-042025×9 Apr56Assembly
2Door seal depth × Part lot L2504-042021×9 Apr77Assembly
3Hinge bolt angle × Part lot L2504-041919×8 Apr87Assembly
4Sealer bead width × Door seal depth19×3 Mar1346Assembly
5Sealer bead width × Hinge bolt angle15×3 Mar1393Assembly

Each finding links to its evidence and to the list of affected units, and exports as an 8D report.

PERFORMANCE18,923 units scored

Inspect fewer units. Find more failures.

0%5%10%15%20%25%30%0%25%50%75%100% 77% of loose-wheel claims in the riskiest 1% 58% of door-leak claims in the riskiest 10% Units inspected, riskiest first random inspection

Scores were produced station by station on production the models had not yet seen, then checked against the warranty claims that followed.

Product views are illustrative, populated with results from a simulated assembly plant.

04 / YOUR FACILITYCONFIGURED, NOT CUSTOM-BUILT

Your products.
Your systems.
Your rules.

Wherever units are built through a sequence of stations and some fail later in test or in the field, IntelliQuality applies. Everything specific to your plant is configuration, set up in hours rather than months.

WHAT YOU PREDICT

Your failures, your costs

Define failure modes from your own defect, return and warranty codes. Tell IntelliQuality what a false alarm and a missed failure cost you, and it sets alerts to match.

YOUR DATA

Your systems and formats

MES and genealogy, historians, test stands, machine data over MQTT, and file exports from any vendor. Each source is mapped once, in the browser.

YOUR LINES

Your structure

Lines, parallel stations, tools, parts, lots, variants and rework loops are described in your plant’s own terms, so every reason reads the way your team talks.

YOUR DECISIONS

Your policies

Choose alert budgets per line and failure mode, who is notified, and whether units are held automatically in your MES or routed to inspection.

YOUR PEOPLE

Your governance

Six roles from operator to administrator. Every change and every decision is recorded in an audit trail, and models go live only with approval.

YOUR MODELS

Your choice of models

IntelliQuality’s models run side by side with your own. All are judged the same way, on the same units, before any of them raises an alert.

FROM A NEW PLANT’S DATA TO SCORED UNITS

  1. Configureabout 2 min per plant
  2. Loadabout 2 min
  3. Learn and scoreabout 18 min for 20,000 units

Measured on four simulated plants that the software had never seen, each set up from its own data and handbook with no code changes.

05 / INTEGRATIONREADY FOR THE SYSTEMS YOU RUN

Plugs into your plant.
Runs where you choose.

IntelliQuality reads from the systems that already hold your production and quality data, and writes its decisions back to them. It is packaged in standard containers, so it runs on a server in your plant or in your cloud, and starts with one command.

YOUR SYSTEMSYOUR DECISIONSMES and genealogyorders, routings, parts, lotsMachines and test standslive over MQTT or filesHistoriansprocess signalsQuality systemsdefects, repairs, auditsWarranty and returnsclaims, field reportsAlert queuereasons in plant termsHolds in your MESwritten back automaticallyRoot cause and 8Downer, window, units to containAPI and exportsyour dashboards and BIINTELLIQUALITY01 Connectmap any format, no code02 Checkdata health and quarantine03 Learnmodels for each failure mode04 Decidescore every unit at every station05 Explainreasons, owner, root cause
06 / PROOFTESTED ON 15 PLANTS, FOUR OF THEM UNSEEN

Tested like it matters.
Before it reaches you.

IntelliMake’s plant simulator generates complete plants, each with its own layout, products, data systems and hidden quality problems. IntelliQuality was scored on 15 of them by an independent examiner. Four were released only after the software was frozen, and it ran on them with no code changes.

0×10×20×30×40×median 18× Plant A ◆42× better than station limits42×Plant B33× better than station limits33×Plant C29× better than station limits29×Plant D23× better than station limits23×Plant E23× better than station limits23×Plant F21× better than station limits21×Plant G19× better than station limits19×Plant H ◆18× better than station limits18×Plant I17× better than station limits17×Plant J17× better than station limits17×Plant K ◆13× better than station limits13×Plant L ◆12× better than station limits12×Plant M12× better than station limits12×Plant N12× better than station limits12×Plant O3× better than station limits3×Ranking quality relative to station limits (PR-AUC ratio)
Better ranking on every plant. ◆ marks the four plants held back until the software was frozen.

ESCAPES FOUND IN THE RISKIEST 1% OF UNITS

IntelliQuality26%
Station limits2%

Mean across 15 plants. The same inspection effort finds about 12 times as many escapes.

  • 4 of 4unseen plants configured and scored with no code changes
  • 45 of 45benchmark runs passed every integrity check
  • 1command to start the whole platform

IntelliQuality is built on research by Prof. Ratna Babu Chinnam and Dr. Sujeet Shrestha at Wayne State University, on predicting quality from interactions across stations.

Benchmark results are from simulated plants and are illustrative.

07 / NEXT STEPBRING US ONE PROBLEM

Where does quality
cost you the most?

Bring one line, one failure that keeps coming back, and a few months of data. We will configure IntelliQuality to your plant and show you what it finds.